- Product Detail
-
■Product description
Stranded Stainless Steel Tube OPGW (SSST / Multi-Tube) is an overhead ground wire with integrated optical fibers. Instead of a single central tube, the optical fibers are housed in multiple stainless-steel loose tubes arranged within the stranded cable. The outer metallic strands are selected to meet the required mechanical strength and electrical thermal rating for transmission line service. This design is widely used when a project requires higher fiber counts and flexible fiber unit configuration.
■Typical construction
1) Optical tube units (multi-tube)
Multiple stainless-steel loose tubes positioned within the stranded cable
Water-blocking filling compound (gel) inside tubes for moisture protection and fiber cushioning
Single-mode optical fibers placed with appropriate slack/excess length (design dependent)
Tube sealing method defined by the design and verified by the agreed test plan
2) Metallic stranded layers
Stranded metallic wires around the tube units, typically a combination of:
Aluminum-clad steel (ACS) wires
Aluminum alloy (AA) wires
Optional steel strands (project dependent)
Single or multiple stranded layers according to required RTS/RBS and short-circuit rating
3) Water-blocking (options)
Water-blocking yarns/tapes in cable interstices when required
Protective compounds for stranded layers depending on environment and utility practice
■Key features
Multi-tube fiber layout supports a wide range of fiber counts and routing plans.
Fully metallic construction suitable for long-term overhead installation.
Flexible mechanical/electrical design through strand material selection and cross-section sizing.
Fiber protection provided by gel-filled stainless-steel tubes and controlled fiber placement.
■Standards and typical compliance
IEEE 1138 – OPGW construction, performance, and testing (commonly specified)
IEC 60794-4-10 – aerial optical cables along power lines (OPGW family)
IEC 60793 / IEC 60794 – optical fiber and cable test methods
ITU-T fiber recommendations (e.g., G.652, G.655), as specified
■Technical specification
1.Optical specification (selectable)
Item Specification Fiber type Single-mode per ITU-T (e.g., G.652.D, G.655) or as specified Fiber count Project-specified; selected based on tube count/size and fiber layout Fiber protection Gel-filled stainless-steel loose tubes + optional water-blocking system Fiber identification Standard color sequence; fiber mapping list supplied with delivery Optical performance Attenuation/dispersion/PMD declared by the selected fiber specification and provided in the final datasheet 2.Stainless steel tube specification
Item Specification Tube material Stainless steel Tube configuration Multiple loose tubes (quantity and dimensions per design) Filling Water-blocking compound (gel) Sealing Defined by the final design and validated by agreed tests 3.Metallic strand specification (selectable)
Item Specification Strand materials ACS, AA, optional steel (as specified) Layer count Single or multiple layers (per mechanical/electrical target) Lay direction S or Z (as specified) Lay length Declared by layer in the final drawing/datasheet Surface condition Material-appropriate finish and corrosion protection per specification 4.Mechanical performance (guaranteed per design)
Parameter How it is specified RTS / RBS Guaranteed minimum breaking strength of the completed cable EDS Utility-specified everyday stress for sag-tension design Outer diameter (OD) Guaranteed for the supplied design Weight Guaranteed for the supplied design Elastic modulus Declared for the completed cable design Coefficient of thermal expansion Declared for the completed cable design Minimum bending radius Declared for installation and permanent condition Vibration performance Evaluated per project requirements and agreed methods 5.Electrical performance (guaranteed per design)
Parameter How it is specified DC resistance Declared at reference temperature for the completed cable Short-circuit capacity Declared as thermal rating (commonly I²t, kA²·s) and/or current-duration limits Maximum permissible temperature Declared for continuous operation and short-circuit event (per specification) Ground wire function Provided by the metallic cross-section and overhead installation position ■Testing and inspection
(Per contract: type tests / routine tests / acceptance tests.) Typical scope may include:
Dimensional checks (OD, tube/strand count, lay lengths)
Mechanical verification (breaking strength and elongation behavior)
Electrical verification (DC resistance; short-circuit capability per agreed method)
Optical verification (fiber count, continuity, attenuation at specified wavelengths)
Tube integrity checks (sealing and water-blocking performance per agreed plan)
■Packaging and delivery
Supplied on reels suitable for overhead cable transport and stringing
Reel length, gross weight limit, and labeling per purchase order
Delivery documents typically include: packing list, cable marking record, fiber schedule, and test reports with the final guaranteed datasheet
■Ordering information
- To provide a buildable design and guaranteed datasheet, please specify:
- Installation environment (normal / coastal / industrial pollution)
- Required fiber count and fiber type (e.g., G.652.D / G.655)
- Target OD and weight limits (especially for shield-wire replacement)
- Required RTS/RBS and span data (wind/ice loads, ruling span)
- Required short-circuit rating (I²t or current-duration) and temperature limits
- Preferred strand mix (ACS/AA) if mandated by a utility standard
- Reel length requirement and transport constraints
Stranded Stainless Steel Tube OPGW (SSST) – Multi-Tube Optical Ground Wire
Stranded Stainless Steel Tube OPGW (SSST / Multi-Tube) is an overhead ground wire with integrated optical fibers. Instead of a single central tube, the optical fibers are housed in multiple stainless-steel loose tubes arranged within the stranded cable. The outer metallic strands are selected to meet the required mechanical strength and electrical thermal rating for transmission line service. This design is widely used when a project requires higher fiber counts and flexible fiber unit configuration.
Subcategory:
Key Words:
Factory
FAQ
How can I get a quotation?
Simply send us your inquiry with detailed specifications (product type, quantity, standards). Our sales team will provide a quotation within 24 hours.
Could I visit your factory?
Yes, we welcome and encourage factory visits. It provides an excellent opportunity for clients to gain firsthand insight into our production processes, technical capabilities, and quality control standards.
What payment methods do you accept?
We accept T/T, PayPal, and L/C at sight. Other options may be negotiable depending on the order.
How do you ship the products?
We support multiple shipping options: 1.Express (DHL, FedEx, UPS, TNT) for small orders; 2.Air freight or sea freight for bulk shipments; 3.EXW, FOB, CIF, and DDP terms are available.
What are your main export markets?
Our products are widely used in telecom operators, data centers, ISPs, and system integrators across Asia, Europe, North America, and the Middle East.
Do you provide technical support?
Yes. Our engineering team offers professional technical support, including product selection, network design advice, and troubleshooting assistance.