96-Fibers MPO/MTP High-Density Patch Panel
96-Fibers MPO/MTP High-Density Patch Panel
8.jpg
7.jpg
7f92d2e0-3fc4-4a12-af83-cb2308db379a.png
  • Product Detail
  • ■Product Description

    The Bynet 96-Fiber MPO/MTP Patch Panel is designed for ultra-high-density fiber optic management in large-scale data centers, telecom rooms, cloud computing facilities, and backbone cabling systems. It supports up to 96 fibers in a compact 2U rack-mount enclosure, with 3U options available for larger or customized configurations.

    The panel supports 8 × 12-fiber MPO/MTP or 4 × 24-fiber MPO/MTP connections, providing a reliable and space-saving solution for high-capacity fiber distribution, trunk cable management, and cross-connect applications.

    It is available as a direct MPO/MTP adapter patch panel or as an MPO/MTP cassette-based patch panel, allowing flexible deployment for 40G, 100G, 200G, and 400G optical networks.


    ■Product Features

    • Supports up to 96 fibers in a compact 2U rack-mount design
    • Available with 8 × 12F MPO/MTP or 4 × 24F MPO/MTP configurations
    • 3U rack-mount version available for customized high-capacity applications
    • Modular drawer-style design for easier installation, inspection, and maintenance
    • Supports MPO/MTP adapter panels or MPO/MTP-to-LC cassette modules
    • Front and rear access for simplified cable routing and maintenance
    • Integrated cable management with bend-radius protection
    • Built-in labeling area for clear port identification
    • Rear cable strain relief for secure trunk cable management
    • Supports OS2, OM3, OM4, and OM5 fiber types
    • Male or female MPO/MTP connectors available
    • Supports Type A, Type B, and Type C polarity
    • Key-up to key-down or key-up to key-up adapter orientation optional
    • Standard loss and low-loss performance options available
    • Suitable for 40G / 100G / 200G / 400G high-speed optical networks
    • Loaded or unloaded configurations available
    • Custom design available upon request

    ■Product Configuration Options

    Option 1: MPO/MTP Adapter Patch Panel

    This version is designed for direct MPO/MTP trunk cable patching and cross-connect applications.

    ItemDescription
    Front InterfaceMPO/MTP adapter ports
    Rear InterfaceMPO/MTP trunk cable connection
    Fiber Capacity96 fibers
    Typical Configuration8 × 12F MPO/MTP or 4 × 24F MPO/MTP
    ApplicationBackbone cabling, MPO trunk cable management, high-density cross-connect

    Option 2: MPO/MTP Cassette Patch Panel

    This version is designed for MPO/MTP to LC breakout applications.

    ItemDescription
    Front InterfaceLC duplex adapters
    Rear InterfaceMPO/MTP input
    Fiber Capacity96 fibers
    Typical Configuration48 × LC duplex ports
    Application40G to 10G breakout, 100G to 25G breakout, high-density server/switch interconnection

    ■Technical Specifications

    ParameterSpecification
    Product Name96-Fiber MPO/MTP Patch Panel
    BrandBynet
    Fiber Count96 fibers
    Rack Unit2U standard, 3U optional
    Rack Standard19-inch rack mount
    MPO/MTP Configuration8 × 12F MPO/MTP or 4 × 24F MPO/MTP
    Front InterfaceMPO/MTP adapter or LC duplex adapter optional
    Rear InterfaceMPO/MTP trunk cable interface
    Adapter TypeMPO/MTP, LC duplex optional
    MPO/MTP Fiber Count12F or 24F
    MPO/MTP GenderMale with pins / Female without pins
    Connector PolishUPC / APC for single-mode; PC for multimode
    PolarityType A / Type B / Type C optional
    Adapter KeyKey-up to key-down / Key-up to key-up optional
    Fiber TypeOS2 / OM3 / OM4 / OM5
    Insertion LossStandard ≤ 0.35 dB; Low loss ≤ 0.20 dB optional
    Return LossSM UPC ≥ 50 dB; SM APC ≥ 60 dB; MM ≥ 30 dB
    Test WavelengthSM: 1310 / 1550 nm; MM: 850 / 1300 nm
    Housing MaterialCold-rolled steel or aluminum alloy
    Surface FinishBlack powder-coated
    ColorBlack standard, customized color optional
    Dimensions2U: 482.6 × 300 × 88.9 mm; 3U optional
    Mounting TypeDrawer-style sliding tray, fixed type optional
    Cable EntryRear cable entry, side cable entry optional
    Cable ManagementFront and rear cable management with bend-radius protection
    LabelingPort number label, customized label optional
    Operating Temperature–20°C to +70°C
    Storage Temperature–40°C to +85°C
    ComplianceIEC 61754, IEC 61755, TIA/EIA-568, RoHS, REACH
    Test ReportAvailable upon request

    ■Fiber and Adapter Color Options

    Fiber TypeTypical Color
    OS2 Single-modeYellow cable jacket, blue or green adapter
    OM3 MultimodeAqua
    OM4 MultimodeErika violet or aqua
    OM5 MultimodeLime green

    ■Polarity Options

    Polarity TypeDescription
    Type AStraight-through polarity
    Type BReversed polarity
    Type CPair-flipped polarity
    CustomizedAvailable upon request

    ■Ordering Information

    Example part number:

    BY-MPO-PP-96-2U-OM4-12F-F-B-LL

    CodeDescription
    BYBynet
    MPO-PPMPO/MTP Patch Panel
    9696 fibers
    2U2U rack-mount
    OM4Fiber type
    12F12-fiber MPO/MTP
    FFemale connector
    BType B polarity
    LLLow loss

    ■Common Model Options

    ModelDescription
    BY-MPO-PP-96-2U-OS2-12F-F-A96F 2U MPO/MTP Patch Panel, OS2, 12F MPO/MTP Female, Type A
    BY-MPO-PP-96-2U-OM3-12F-F-B96F 2U MPO/MTP Patch Panel, OM3, 12F MPO/MTP Female, Type B
    BY-MPO-PP-96-2U-OM4-12F-M-B-LL96F 2U MPO/MTP Patch Panel, OM4, 12F MPO/MTP Male, Type B, Low Loss
    BY-MPO-PP-96-2U-OM5-24F-F-A96F 2U MPO/MTP Patch Panel, OM5, 24F MPO/MTP Female, Type A
    BY-MPO-LC-PP-96-2U-OM4-12F-F-B96F 2U MPO/MTP-to-LC Cassette Patch Panel, OM4, Type B

    ■Customization Options

    Bynet provides flexible customization for different project requirements.

    • 2U or 3U rack-mount housing
    • Drawer-style sliding tray or fixed panel design
    • Loaded or unloaded patch panel
    • MPO/MTP adapter panel or MPO/MTP cassette panel
    • 12F or 24F MPO/MTP interface
    • Male or female MPO/MTP connector
    • UPC, APC, or PC polish type
    • OS2, OM3, OM4, or OM5 fiber type
    • Type A, Type B, or Type C polarity
    • Standard loss or low-loss performance
    • Key-up to key-down or key-up to key-up adapter orientation
    • Customized port labeling
    • Customized adapter color
    • Customized package and product label

    ■Applications

    • High-capacity data center infrastructure
    • Telecom backbone and metro network distribution
    • Cloud computing and enterprise network environments
    • High-density server, switch, and storage interconnections
    • 40G / 100G / 200G / 400G optical network cabling
    • MPO/MTP trunk cable management
    • Backbone cabling and cross-connect systems
    • Modular fiber management in rack systems

    ■Package Includes

    • 1 × 96-Fiber MPO/MTP Patch Panel
    • MPO/MTP adapters or cassette modules, according to configuration
    • Rack-mounting screws
    • Cable management accessories
    • Port labels
    • Dust caps
    • Test report, optional

    ■Quality Assurance

    Each Bynet 96-Fiber MPO/MTP Patch Panel is manufactured under strict quality control and can be factory-assembled and tested before shipment. Standard and low-loss configurations are available to meet different performance requirements in high-speed optical networks.

    100% factory testing and customized test reports are available upon request.

96-Fibers MPO/MTP High-Density Patch Panel

The Bynet 96-Fiber MPO/MTP Patch Panel is designed for ultra-high-density fiber optic management in large-scale data centers, telecom rooms, cloud computing facilities, and backbone cabling systems. It supports up to 96 fibers in a compact 2U rack-mount enclosure, with 3U options available for larger or customized configurations. The panel supports 8 × 12-fiber MPO/MTP or 4 × 24-fiber MPO/MTP connections, providing a reliable and space-saving solution for high-capacity fiber distribution, trunk cable management, and cross-connect applications. It is available as a direct MPO/MTP adapter patch panel or as an MPO/MTP cassette-based patch panel, allowing flexible deployment for 40G, 100G, 200G, and 400G optical networks.

Key Words:

Factory

factory
factory
factory
factory
factory
factory

FAQ

How can I get a quotation?

Simply send us your inquiry with detailed specifications (product type, quantity, standards). Our sales team will provide a quotation within 24 hours.

Could I visit your factory?

Yes, we welcome and encourage factory visits. It provides an excellent opportunity for clients to gain firsthand insight into our production processes, technical capabilities, and quality control standards.

What payment methods do you accept?

We accept T/T, PayPal, and L/C at sight. Other options may be negotiable depending on the order.

How do you ship the products?

We support multiple shipping options: 1.Express (DHL, FedEx, UPS, TNT) for small orders; 2.Air freight or sea freight for bulk shipments; 3.EXW, FOB, CIF, and DDP terms are available.

What are your main export markets?

Our products are widely used in telecom operators, data centers, ISPs, and system integrators across Asia, Europe, North America, and the Middle East.

Do you provide technical support?

Yes. Our engineering team offers professional technical support, including product selection, network design advice, and troubleshooting assistance.

Related Products

Product Inquiry

We will contact you within one business day. Please pay attention to your mail.

%{tishi_zhanwei}%